Tapelight_ProductGuide_2023
8/9

※ For Kinetic TokiLeds, dimmers cannot be used.※20pcs/setPress-fit fixed type, Made of stainless steel,Applicable panel thickness: 0.8 to 1.6 mm, Can be used outdoors, Recommended mounting hole diameter: Φ9.5mm※ The above numbers are recommended values. SH-02/20Socket holders (20pcs/set)The fit differs depending on the material of the panel, so please check the actual product (we will provide a sample item).VT-100Binding ties (100pcs/set)FL-TAN2FL lead wire 2m attachment processingFL-TAN5FL lead wire 5m attachment processingFL-WTANFL both ends lead wire attachment processingFL-ED10FL end caps (10pcs/set)Silicone caps for panel mounting (For Standard TokiLeds, Kinetic TokiLeds) (20pcs/set)WP-FL01C/20WP-L01C/20For replacement silicone caps (20pcs/set)Φ613.62123.520LED SpacingFantazic LinePower supplies(mm)AWG18×2Fantazic Line may be panel-mounted with our panel fasteners. Sockets are pushed through the hole in the panel from behind, and the fastener is pressed in place from above.Commercially available a box screwdriver/nut driver (10mmacross flats, for M6) for press-fitting is easy to use.The distance from the power supply to the fixture, and the load of the fixture, will determine the proper size of secondary wire. Fixtures require an individual lead. If additional wire needs to be attached, refer to the recommendation in this chart.Silicone capRecommended hole sizeΦ9.5mmSH-02/20※20pcs/setSocket holders Standard TokiLeds AWG14 27mSH02Panelthicness0.8-1.6mmSilicone caps for panel mountingWP-FL01C/20Kinetic TokiLedsAWG14 27m1 For tree applications, fixtures are generally installed along the treeline (fig. A). Wrapping strands around limbs is not recommended as this will adversely effect tree growth. 2 Binding ties may be used at key points to secure strands without prohibiting plant growth.3 Fixtures suspended between branches can be adversely affected by wind and rain and lead to breakage. Please install so fixtures run along branches and trunks.VT-100※100pcs/setIt is possible to connect the lighting fixtures and a remotely set power supply with an appropriate lead wire. Refer to the table for lead wire sizes and length limitation.The extension distance is a guideline distance for the fixture's maximum capacity. Depending on the type of power supply, lead wire, and number of LEDs, it may be possible to extend it further. Please contact us for more information.Binding ties Standard TokiLeds& Kinetic TokiLeds13PRODUCT GUIDEFor Panel MountingRecommended Lead Wire Size and Length LimitationFor illuminating treesPRODUCT GUIDE14ABOptionsSpecificationsProduct CompornentInstractions

元のページ  ../index.html#8

このブックを見る