Set the mounting base in the orientation shown in the left figure.150°Wall1 lx15m5 lx5 lxFocal Line requires power supplies.No longer than AWG18x2C 40m1. Architectural use Facades, Uplighting, Mullions, Eaves, etc. Produces narrow light effects.2. Event use Lighting a pathway across ground or highlighting a wall, etc.Refer to Page 9 for the power supply and dimming of Focal Line.91°Mounting holes70°Pivot angleDrain holeBushingCG Image176Fixture headKnurled nutCanopyMounting baseRubber gasketLead wire Φ15 outlet5.568Mounting baseMounting holesFocal LineCG imageΦ80Φ115Φ120LDCC-15W-700DALILED DriverCurrent = 700mAWattage = 2.1WWeight = 770gMain Materials = Aluminum, Stainless Steel & PC For Wall Mounting LED Color3000K5000KPointFixture ColorB : BlackBecause of the unique polarized lens, it is possible to maintain a narrow light distribution and illuminate only the walls and pillars you want to illuminate.150°Rotation angle :When irradiation direction is downwardIrradiation experimentRecommended uses for this seriesOriginal designSpecial lens (patented)Equipped with a uniquely designed polarized light distribution lens78PointYou can create an effect that has been difficult to achieve in the past, long linear beams of light. In addition to architectural displays, fixtures can also be used for promotional events.OUTDOORCRI 80IP66700mADALIFor new performance expressionsSpecificationsProduct ComponentSystem FeaturesInstallationLight Distribution(mm)When affixing the fixture to a wall, make sure one of the canopy drain holes is facing downward. Remove the bushing facing downward.Rotation angle :When irradiation direction is upwardFS01-  K-L-B01FOCAL LINE02