PRECAUTIONS ※ 5pcs/set※ One Mounting disk is required for each socket. EXBK-MD/5Mounting disksPlease check the required number of LEDs before placing an order.EX-SH-01/10Please check the required number of LEDs before placing an order.EXBK-MDW/5Please check the required number of LEDs before placing an order.Socket holdersWire-rope adaptorsWire SizeAWG14AWG121. Read all instructions completely before beginning installation.2. Turn off electricity before beginning installation.3. All wiring is to be performed by a qualified electrician.Total LengthWithin 25mWithin 44m1. Exhibitor fixture snaps 5PRODUCT GUIDEdirectly into the Mounting Disk and locks in place.Mounting disk2. Mounting Disks attach with screws.Screw holesWire RopeSocketExhibitor Series can be surface mounted to struc-tures using mounting disks. One disk is required for mounting each socket. The socket can be snapped into the disk first, and the entire assembly screwed in place to the structure.Wire-rope adaptorFor installations to flat panels or extrusions up to 0.8 〜 2.0mm, we offer stainless-steel socket holders. The socket assembly is inserted from below, then the socket holder is pressed in place from above.For festoon applications to a catenary cable, our wire-rope adaptors securely hold each socket in place to a 3 〜 5mm diameter wire rope. Wire rope and all the associated mounting hardware is not provided with the system.Φ32mm hole※ 10pcs/set※ Socket holders are required for each LED. ※ 5pcs/set※ A wire-rope adaptor is required for each socket. EX-SH-01Panel thickness0.8 〜 2.0mmIt is possible to connect the lighting fixtures and a remotely set power supply with an appropriate lead wire. Refer to the table for lead wire sizes and length limitation. The extension distance is a guideline distance for the fixture's maxi-mum capacity. Depending on the type of power supply, lead wire, and number of LEDs, it may be possible to extend it further.Please contact us for more information.Recommended Lead Wire Size and Length LimitationThe distance from the power supply to the fixture, and the load of the fixture, will determine the proper size of secondary wire. Fixtures require an individual lead. If additional wire needs to be attached, refer to the recommendation in this chart.Electronic transformers may not be used. The primary input to the transformer may be dimmed from industry standard phase-control dimmers, also referred to as triac dimmers. While most show very favorable results, there may be compatibility issues with certain makes and models. The following guidelines should be taken into account in selecting the proper dimming device:1. Make sure the dimmer used is suitable for use with mag-netic low-voltage transformers, not electronic low-voltage transformers.2. Some dimmers have a minimum-load requirement. Since 3. Some dimmers not only require a minimum load, but may not function properly at certain levels/loads because they do not interpret an LED load as they do a standard incan-descent load. In such cases, some dimming companies offer a “synthetic load” device to resolve this issue. Check with the dimmer manufacturer in such cases.TransformerLEDs consume so little power, this should be given serious consideration in the selection of the dimmer.Length Limitation4. Tokistar has evaluated a wide range of dimmers, but can-not promise perfect dimming results with every make and model on the market. Additionally, manufacturers of dimmers occasionally make changes to their specifications without notice. Some older generations of a certain model might actually work more fluidly than a newer generation.5. If there is any question on compatibility, consult with us on a case-by-case basis. We work closely with many dimming companies, and can provide samples of our fixtures for compatibility testing if necessary.• Do not extend the lead wire too much, as it is very dangerous.• Please contact us if you want to extend beyond the length of the table.• Select a cable with a capacity, according to the site conditions. Select a cable that conforms to water and weather resistance standards, according to the site environment.4. Installation must comply with the National Electrical Code, or related applicable regulations.5. Turn main supply to magnetic down transformer on only after all connections have been made and tested.6. Use only appropriate magnetic down transformer.FixtureFestoon Mounting with Wire-rope AdaptorsSurface Mounting with DisksPanel-Extrusion Mounting with Socket HolderExhibitor LED series operate with 24VAC magnetic transformer.PRECAUTIONSPRODUCT GUIDE6InstructionsWiring DiagramPower Supplies
元のページ ../index.html#4